Homepage | Set Home | Add to Favorites
Member

Fatech Electronic (Foshan) Co., Ltd.


Products
  • No Category
Search
 

Friends links
  • No link

Ese Lightning Rod (FLR-04/4)
Click image to view full size image
Product: Views:150Ese Lightning Rod (FLR-04/4) 
Unit price: Negotiable
MOQ:
Quantity:
Delivery date: Since the payment date Days delivery
Valid until: Long-term effective
Last updated: 2017-09-17 05:45
  Inquiry
Details



FLR-04 series lightning rods mainly absorbs and stores energy by stimulator from electric field in nature. Reflector and lightning rod tip has a good electrical connection with earth, and in equipotential connection.


Usually, there is electric field strength between Excitor and reflector, when thunder occurred, the electric field strength will rapidly increase, the potential difference between excitor and reflector is roughly equivalent to the potential difference of cloud and earth, and the voltage drop between them which increase quickly will cause the strike tip, and to make sophisticated the surrounding air ionization, a point discharge phenomenon. The electric field between lightning rod's central collection and excitor rapid increase, which cause tip of the air can be produced in a very short ionization and accurate time discharge, because of a large number of the existence of ionizing, so that naturally reduce the Corona effect, produce a expected uplink discharge passage, can quickly and safely volleys lightning discharge to the earth.

Features
- This lightning conductor FLR04 is no electronic type, with long life time
- Protection quality not changed after lightning.
- Cannot be damaged after lightning because of no electronic system
- Different radius of protection model selection
- Will self activation when there is lightning.
- No need maintenance


FLR-04 Lightning rod installation height H = Lightning rod above the level of the protected object height (m)
5 6 7 8 10 15 20 45 60
FLR-04/2 Lightning rod 22 22 23 23 25 25 25 - -
FLR-04/3 Lightning rod 42 42 43 43 43 44 45 - -
FLR-04/4 Lightning rod 61 61 61 61 62 62 63 - -
FLR-04/5 Lightning rod 51 51 52 52 53 53 54 - -

FLR-04 Lightning rod installation height H = Lightning rod above the level of the protected object height (m)
FLR-04/2 Lightning rod 44 44 46 47 48 51 59 - -
FLR-04/3 Lightning rod 57 58 59 60 63 65 70 - -
FLR-04/4 Lightning rod 78 79 79 80 82 84 88 - -
FLR-04/5 Lightning rod 51 51 52 52 53 53 54 - -

FLR-04 Lightning rod installation height H = Lightning rod above the level of the protected object height (m)
FLR-04/2 Lightning rod 50 50 52 52 55 59 74 - -
FLR-04/3 Lightning rod 64 67 68 72 75 83 85 - -
FLR-04/4 Lightning rod 76 78 79 82 85 92 94 - -
FLR-04/5 Lightning rod 87 88 90 92 94 101 103 - -

Inquiry